Frost log
Record the temperature on each morning the hot water fails.
Hot water in Farnworth feels the climate and the contours. Frost reaches condensate pipes on outside walls, high streets give combis weak mains pressure and boilers in outhouses lose heat before the water gets indoors.
Condensing boilers pass mildly acidic water down a plastic pipe; on a cold night such a pipe, if it runs outside, can freeze and put the boiler out of action, leaving no hot water until it thaws. Tell a reader if the boiler cuts out on frosty mornings and where the condensate pipe runs, then add how much of it is outside, if it has any wrapping and if the boiler flashed a fault code overnight.
Houses high on the slope get weaker mains pressure, and a combi that needs a minimum flow to fire may switch off when the pressure dips. Cottages with boilers in lean-tos or outhouses lose heat through long cold runs. Say whether the flow worsens at peak times, whether the boiler stops when a second tap opens, where the boiler stands and how far the pipes run before reaching a tap.
Typical jobs include boilers that lock out in frost, hot water that stops at peak times, cylinders in cold stores that lose heat and taps with a long wait for hot. Farnworth households can say how cold the night was and where the boiler stands, so a reader can judge whether frost, pressure or heat loss in the pipes is the likelier cause.
Note the temperature on mornings the hot water fails and photograph the condensate pipe where it leaves the boiler and any outside run. Clock the wait for hot water at the farthest tap. Do not pour boiling water over a frozen pipe, do not reset the boiler more than once and do not stand in a freezing lean-to with wet hands near the boiler. Note any smell of gas, and write down how long the boiler has run without a service.
Record the temperature on each morning the hot water fails.
Photograph the pipe from the boiler to the drain and say how much is outside.
Note whether hot water fails at breakfast or in the evening.
Estimate how far hot water travels from the boiler to the farthest tap.
In a valley terrace the combi shuts down on frosty mornings and the display shows a fault, while a cottage in the same street loses hot water at breakfast. The terrace household logs five frosts, photographs the white plastic pipe running down an outside wall with no lagging, notes the boiler restarts by midday and says the pipe is about two metres long. The cottage household notes the street is high on the slope and the boiler stands in a lean-to. The picture is a frozen condensate pipe and weak pressure at peak times.
Frozen overnight. Log the frosts.
Peak-hour failures. Note the times.
Chilly surroundings. Say how far the pipes run.
A plastic drain pipe from a condensing boiler that carries mildly acidic water away and can freeze outdoors.
The force of water coming from the street supply, which falls on high ground at busy times.
The least water a combi boiler needs passing through it before it will fire and heat the supply.
Often. Log the frosts and photograph the pipe where it runs outside.
Take great care and note that this is only temporary. Describe what happened.
Perhaps mains pressure. Note the times and whether a second tap is open.
Step outside, leave the switches alone and call 0800 111 999 before any other step.
Not by itself. The opening move is a written reply, and any call comes after a quote you accept.
Log the frosts, photograph the condensate pipe and boiler position, time the hot run to the farthest tap and then post your Farnworth hot-water enquiry with Repairco.