Smell room
Name the room with a musty smell and say where it seems strongest.
Houses in Hindley were built across several generations, and a leak in one of them may start in a pipe of any age: iron from the earliest days, lead where a service pipe has never been replaced, copper from a later refit or plastic from the last few years. Where the water first shows is rarely where it begins.
Ground-floor rooms in colliery-era houses sit over a ventilated void where pipes run in the dark, and a drip there can rot joists for months before the skirting shows a mark. A musty smell, a floor that bounces or a bubble in vinyl is the usual hint. Say which room has the smell, whether the floor has any soft areas, whether an air brick outside is blocked and whether the water bill has risen. If a floorboard is already loose, photograph the void with a torch, keeping your hands clear.
Interwar houses often have an airing cupboard on the landing, a cylinder inside it and pipes running through the floor to the rooms below. A weeping joint on a cylinder connection can drip for months, soaking the cupboard shelf and dampening the ceiling below. Report whether the airing cupboard has a clammy feel, whether the shelf is stained, whether the ceiling underneath has marks, whether the cylinder valves have green or white crust and whether the cupboard floor is dry. Photographs with a torch help a reader a lot.
Pipework and leak work in Hindley covers weeping joints, corroded runs, leaks beneath floors, seepage around cylinders, stained ceilings and pipes that knock or vibrate. The room, the floor and the age of the pipework are the first three details a reader needs.
Press the back of your hand against walls and floors in the affected room and mark any cool or damp spots with masking tape. Check every visible pipe for a bead of moisture at the joints. Slide a sheet of dry card under a suspect valve. Do not pull up a floor without turning off the supply, do not rub green crust off a fitting before photographing it and do not ignore a smell of damp timber.
Name the room with a musty smell and say where it seems strongest.
Check outside whether the air bricks near that room are blocked.
Photograph any green or white crust on the cylinder connections.
Slip dry card under a valve and see whether it marks.
In a colliery-era house, the dining room has a musty smell and the vinyl floor has a bubble near the hearth. The householder presses the floor and finds it soft, photographs the air brick outside which is clogged with leaves, and notes the water bill has crept up. In the airing cupboard upstairs she finds a green crust on a cylinder valve. A reader sees two possible leaks, one beneath the floor and one at the cylinder, and a ventilation problem that makes both worse.
Voids and soft boards. Check the air bricks.
Cylinder joints and stained shelves. Photograph the valves.
New pipes joined to old. Tape any damp spot.
A brick with holes in it set into an outside wall to let air move through the space under a floor.
The empty space beneath a ground floor where pipes and joists sit.
A small valve on the pipework of a hot-water tank that can be closed to isolate it.
It could. Say where the smell is strongest and whether the floor feels soft.
It can trap damp under the floor, so clear it gently and note the weather.
Possibly a slow one. Photograph it and wipe the area dry to see what returns.
Only if the supply is off and you know where pipes run. Describe the room first.
A written reply, with any visit left until you have accepted what is proposed.
Press the floor and walls, tape any damp spot, check the air bricks outside, photograph the cylinder valves, and then send your Hindley leak details to Repairco.
Submitting a repair enquiry does not confirm an appointment or payment.