Crack record
Mark the tip of any crack in pencil, add a date and photograph it by a ruler.
A ceiling that cracks is a ceiling that moves, and a rose or a pendant fixed to it moves with it. In Westhoughton's older villages that is a familiar story, while on the estates the faults are more often dimmers and bulbs.
Houses on ground that has settled may show a thin crack across a ceiling that passes beside or through a ceiling rose, and the cable behind can be strained or the fixing loosened. A pendant on that rose may tilt. Say where the crack runs, whether it has grown, whether the rose looks pulled from the ceiling, whether the light flickers and when the ceiling was last decorated.
Estate rooms with a pendant or spotlights on a dimmer are prone to buzzing, flickering and failing, especially when LED bulbs are used on dimmers meant for older bulbs. Say what bulbs are fitted, what type the dimmer is, whether the light buzzes when dimmed, whether it flickers at low settings and how many fittings share the dimmer. Mention whether the dimmer was fitted with the room or added later, and whether the bulbs were changed at the same time, since a mismatch often begins on the day someone swaps the lamps.
Typical complaints are crack lines near roses, loose pendants, buzzing dimmers, flicker at low levels and bulbs that fail quickly. Westhoughton households can describe the ceiling and the bulb type, so a reader can judge whether movement, a worn connection or a mismatch between bulb and dimmer is at the root.
Draw a dated pencil line at the tip of any ceiling crack and photograph it against a ruler. Note the bulbs fitted and the dimmer's label if it is visible. Switch off and photograph the rose from the floor. Do not paint over a crack without recording it, do not swap bulbs on a live fitting and do not turn a dimmer past its stop to force it. Say whether dimming occurs on all or only some circuits.
Mark the tip of any crack in pencil, add a date and photograph it by a ruler.
Note the bulb type and the dimmer's label, since mismatches cause buzzing.
Say whether a pendant hangs level and whether it has changed.
Say at which setting the light flickers or buzzes.
In a village house, a household finds a hairline crack has opened across the lounge ceiling close to the rose and the pendant has begun to tilt, while in the estate house next to it the dimmer buzzes at low levels. The village household pencils the crack end with the date and photographs it beside a ruler, switches the light off and photographs the rose, notes the pendant was level a year ago and says the room was painted last spring. The estate household notes LED bulbs on an old dimmer. A reader sees movement in one house and a bulb mismatch in the other.
Moving fixings. Date each crack.
Buzzing and flicker. Note the bulb type.
Frayed cable. Photograph the holder.
A bulb that gives light from diodes rather than a filament, using little power but sometimes clashing with older dimmers.
A very fine crack in plaster, often a sign of small movement in the structure behind.
The range of power a dimmer can control, printed on its back or its label.
Possibly. Date it, photograph it with a ruler and switch the light off meanwhile.
Often a bulb and dimmer mismatch. Note the bulb type and the setting.
Not before it is recorded. Take a picture and write down the date.
Please not. Switch off at the board first.
No. Writing comes before visiting, and visiting waits until you have said yes to a price.
Pencil and date the crack, photograph the rose and tilt, note the bulb and dimmer type and then send your Westhoughton ceiling light enquiry to Repairco.
Submitting a repair enquiry does not confirm an appointment or payment.