Paper test
Put dry paper under each valve for an hour and note which gets damp.
Westhoughton radiators and hot water fail in ways that depend on the age of the house. Older village houses on moved ground see valves weep and joints strain, while estate houses see immersions trip and pressure fall.
In older houses where floors and walls have shifted, radiator valves and the joints beneath them take the strain, and a slow weep can leave a stain under a radiator or beneath a floor. Say which radiators have marks beneath, whether valves feel loose, whether pressure has been dropping, whether the carpet near a radiator is damp and whether cracks run through the walls nearby.
Estate houses often have an unvented or vented cylinder with an electric immersion as backup, and a boiler that tops up pressure through a filling loop. An immersion that trips, a thermostat that has failed or an expansion vessel that has lost its charge can each give tepid water or falling pressure. Say whether the immersion is used, whether the breaker trips when it is on, what the pressure gauge shows and whether it rises when heating.
Typical complaints include valves that weep, radiators that need frequent bleeding, tepid taps, immersions that trip and pressure that falls and rises. Westhoughton households can describe where marks appear and how the pressure behaves, so a reader can tell a strained joint from an expansion fault or a failed element.
Place a dry piece of paper under each radiator valve for an hour and see which become damp. Photograph the pressure gauge cold and hot. Note the immersion switch's position and whether its breaker trips. Do not open a cylinder's safety valve, do not tighten a valve repeatedly and do not run an immersion that trips again and again. Add the make and approximate age of the cylinder if its label can be read from the cupboard door, and say whether the boiler and the cylinder were fitted at the same time. If you smell gas, call 0800 111 999.
Put dry paper under each valve for an hour and note which gets damp.
Photograph the gauge before heating and an hour into a run.
Say whether the immersion is used, and whether its breaker trips.
Date any crack on a wall behind a radiator that weeps.
In one estate house the hot water is tepid unless the immersion is switched on, and the breaker trips after twenty minutes, while a village relative notices a damp patch below a radiator valve. The estate household photographs the gauge cold and hot, notes the pressure rises to near the limit, records the breaker trip time, places paper under the radiator valves and finds one damp, and says the cylinder is a decade old. A reader sees a failing immersion element and an expansion issue.
Weeping valves. Use the paper test.
Trips and tepid water. Time the trip.
Expansion faults. Photograph the gauge.
An electric heating element fitted inside a hot water cylinder that warms the water directly.
The valve at the end of a radiator that controls how much hot water flows into it.
A valve on a cylinder or boiler that opens to release pressure if it rises too far.
Probably the element. Time the trip and leave the immersion off meanwhile.
Please not. Try the paper test and describe the stain.
Not near the limit. Photograph the gauge cold and hot.
Get out of the building, leave switches alone and phone 0800 111 999.
No. A written answer is the next step, and a visit comes only if you accept a quote.
Put paper under each valve, photograph the gauge cold and hot, note any breaker trips and then post your Westhoughton radiator and hot water enquiry with Repairco.
Submitting a repair enquiry does not confirm an appointment or payment.