Discharge pipe
Photograph the outside pipe and say whether it runs steadily or in bursts.
Whitefield's sealed hot-water systems depend on valves and vessels most householders never see. When a discharge pipe runs, a condensate pipe overflows or a shower scalds, the cause is hidden but the risk is real. Nobody is sent by this page; it keeps your note once things are safe.
An unvented cylinder carries a temperature and pressure relief valve that discharges through a pipe to the open air. A pipe that runs steadily or spits hot water signals an overheating or a failed expansion vessel. Say whether the outside pipe is running, whether the water is hot, how long it has run, what the pressure gauge reads and whether the cylinder has been serviced.
A condensing combi boiler drains acidic water through a plastic pipe that can freeze or block, shutting the boiler down and sometimes spilling water. A scalding shower may follow a pressure fault. Say whether the boiler shows a fault, whether the condensate pipe outside is iced or dripping, whether the shower temperature is unpredictable and whether a smell of gas has been noticed.
Discharging cylinders, blocked condensate pipes, boilers that shut down and showers that scald are the usual cases. Telephone your insurer, the landlord or a tradesman whose number you hold before anything else; the form logs a date and arranges no visit.
Flick the immersion's spur to off and press the boiler's isolator off. Do not touch a discharge pipe running hot, do not stand beneath it and keep children and pets away. Photograph the discharge pipe and the boiler display from a safe distance, writing the time on each. If anyone is hurt, or an alarm sounds, leave the house and ring 999.
Photograph the outside pipe and say whether it runs steadily or in bursts.
Write the pressure on the gauge and when you read it.
Look at the pipe outside and say whether it is iced, blocked or dripping.
Say whether the shower scalds without warning or swings.
On a freezing morning, a household in an extended semi sees the cylinder's discharge pipe spitting hot water onto the patio and the combi boiler locked out with a fault code, while the en-suite shower scalds without warning. They switch the immersion off at its spur, isolate the boiler, keep clear of the pipe, photograph the discharge, the display and the frosted condensate pipe from a safe distance with the hour on every picture, and ring their insurer. They mention that nobody has serviced the cylinder. A reader sees a discharging relief valve and a frozen condensate pipe.
Discharge pipes that run. Photograph from afar.
Freezing and blockage. Note the ice.
Sudden scalding. Record the swings.
A safety valve on a sealed cylinder that opens to release water if heat or pressure climbs too high.
A slim plastic pipe that carries acidic water from a condensing boiler away to a drain.
A switch or valve that cuts an appliance off from its power or water supply.
Switch the immersion off at its spur, isolate the boiler and keep well clear of the pipe.
Warm, not boiling, water only, and only if the boiler is off. Photograph it first.
Out of the house first, then 0800 111 999 from a safe distance, touching nothing electrical on the way. Operate nothing electrical on the way.
Please not. Switch the water heating off and describe the swings.
No. Posting it moves nobody to the extension, so your insurer, the landlord or a tradesman you know are the first calls, and a visit comes up for decision afterwards, against a quote.
Flick the immersion spur off, isolate the boiler, keep clear of the discharge and photograph the pipe, the display and the frosted condensate pipe with the hour on each; then compose the Whitefield hot-water enquiry for Repairco.
Submitting a repair enquiry does not confirm an appointment or payment.