Original against added
Mark which radiators are original and which were added later.
Whitefield's extended semis have grown more rooms than their heating was built for. A radiator in a new kitchen extension hangs on a pipe tapped from an old one, and the conservatory, if it has a radiator at all, sits at the end of the line.
Extensions add radiators by tapping into existing pipes, and a pipe sized for four rooms may now serve six. The new rooms warm last and slowest, and the old ones may run hot while the new ones lag. Say which radiators were added, when, how long the new run is, whether the extension is built over a slab or a void and whether its radiators are as hot as the others. If the builder left any pipework visible in a cupboard or under a unit, take a picture, because a joint in a tight space tells a reader more than a description of the room.
Conservatories rarely suit central heating, being mostly glass, and a radiator there either loses all its heat or tempts a household to leave doors open. Combis moved into lofts to free a kitchen cupboard sit at the top of the system and may starve of pressure. Say whether the conservatory has a radiator, where the boiler stands, what the pressure reads and whether the boiler cuts out when the loft room is in use.
Typical jobs include extension radiators that stay cold, rooms that take hours to warm, boilers that lock out when the system is hot and pressure that varies from one season to the next. A household can describe what was added and when, so a reader judges whether it is a pipe too small, a missing balance or a boiler placed awkwardly.
Draw the heating as you understand it, marking which radiators are original and which added. Run the heating for an hour and feel each radiator, noting hot, warm and cold. Photograph the boiler, its display and its position. Gas in the air means walking out of the house and calling 0800 111 999. Closing old radiators to push heat to new ones, heating a conservatory with the garden doors open and bleeding a hot radiator are best avoided.
Mark which radiators are original and which were added later.
Estimate the length of pipe serving the extension.
Say whether it has its own radiator and how often doors are left open.
Note whether the boiler is in a loft and what the pressure reads.
In a semi extended at the back the kitchen extension radiator is barely warm while the old dining-room one runs hot, and the loft-room combi cuts out when the shower runs. The household draws the system marking added radiators, run the heating for an hour and feel each, photograph the boiler in the loft with its display, estimate the new pipe at eight metres and says the conservatory has no radiator. The pattern is a long extension run, an unbalanced system and a boiler placed high.
Late heat. Estimate the run.
Mostly glass. Say how it is heated.
Pressure at the top. Photograph the display.
A new branch taken off an existing heating pipe to feed an extra radiator.
A heating circuit in which some radiators get far more hot water than others.
A boiler fitted in a roof space, often to free a kitchen cupboard, which can suffer from low pressure.
Possibly. Mark original and added radiators and estimate the run.
Please not. Describe the temperatures and let a reader judge.
Perhaps pressure. Note the reading and the display.
Out of the house, then 0800 111 999 from outside, then everything else.
Not on sending. A reply arrives in writing, and anyone calling follows a quote you accept.
Draw the system with added radiators marked, feel each radiator after an hour, photograph the boiler and display and then lodge your Whitefield heating enquiry with Repairco.
Submitting a repair enquiry does not confirm an appointment or payment.