Cellar damp
Note whether the cellar is damp or smells musty and how high the damp reaches.
Atherton's older rows were heated by coal until late, and modern systems were fitted into spaces that were never planned for them: cellars, cupboards under stairs and rooms with solid walls. Estate houses add pipes buried in floors that are hard to reach.
A boiler in a cellar or beneath the stairs works in a damp, tight place with a flue that may run a long way. Cellar damp attacks the electrics and the casing, and condensate pipes can freeze in an unheated space. Say where the boiler is, whether the cellar is damp, how the flue leaves, whether the condensate pipe runs outside, whether the boiler ever fails to light and whether there is any smell of soot. A photograph of the label on the boiler, with its model and year, helps whoever you ring judge how old the equipment is.
Estate houses with pipes laid in a concrete floor lose heat to the slab, and a leak there is difficult to find. A pressure that keeps falling is the clue. Describe whether the floor feels warm in one spot, whether the gauge falls between top-ups, whether radiators on the ground floor are cooler than those upstairs and whether you hear a faint hiss near a wall. Add how long the pressure gauge takes to fall from its normal reading to a warning one, since that rate says how large a leak might be.
Heating faults in Atherton include boilers in damp cellars that cut out, frozen condensate pipes, falling pressure from buried leaks and radiators that lose heat to solid walls. A reader helps by saying where the boiler sits and how the floor feels, since cellar damp and buried leaks are the commonest causes here.
Look at the boiler cupboard or cellar with a torch and photograph the casing, the flue exit and the pipe outside. Feel the floor for a warm patch and photograph the pressure gauge across several days, with a note of the time of each picture. Do not open the boiler, do not block the flue with stored items and do not stay in the house if there is a smell of gas or soot; go outside and ring 0800 111 999.
Note whether the cellar is damp or smells musty and how high the damp reaches.
Check that nothing is stored against the boiler or the flue.
Feel the floor for a warm spot and mark it with tape.
Write down the pressure on several mornings.
In a cotton terrace the boiler sits in a damp cellar and fails to light on cold mornings, while in an estate house the pressure falls weekly and the hall floor feels warm in one spot. The households photograph the casing, the flue and the damp line, note that boxes are stacked beside the boiler, mark the warm patch with tape, and log the gauge over a week. A reader sees damp harming a boiler and a probable buried leak.
Damp and tight. Clear the space.
Warm patches. Mark with tape.
Radiators losing heat to stone and brick. Note the walls.
The duct that carries a boiler's exhaust gases outside.
A concrete floor laid directly on the ground, sometimes with pipes buried in it.
A wall without a cavity, which loses heat more quickly than a modern cavity wall.
It might. Photograph the casing and the damp line and note the mornings.
Yes; keep the space clear and say what is stored there.
Possibly. Mark it with tape and log the pressure.
No; go outside and ring 0800 111 999, then note what you smelt.
Atherton hears back in typing first, and a caller follows a quote you accept.
Photograph the boiler and the flue, clear the space round it, mark the warm patch, log the gauge, and then send your Atherton heating enquiry to Repairco.
Submitting a repair enquiry does not confirm an appointment or payment.