Bleed record
Say when each attic radiator was last bled and how much air came out.
Radiators in Horwich work harder than most. The wind strips heat from the walls they sit against, loft rooms take the end of every pipe run and valves in cold porches sit unused for months.
Loft rooms and attic bedrooms get the last of the heat, at the end of a long run, and air collects in their radiators because they sit at the highest point. A panel that is hot at the bottom and cold across the top needs bleeding more often than the rest. Say how often the attic radiator is bled, how much air comes out, whether it is cool at the far end of the panel, whether the pump hums and how the room compares with the one below.
Radiators on gable walls lose heat to the wind through masonry and gaps, while those in porches and cold outhouses spend months switched off, their valves seizing. A seized valve either will not open or will not close, and a pin that sticks leaves the radiator hot all summer. Say which valves are stiff, whether the pin moves when pressed, whether any radiator is hot when it should be off and whether the gable wall feels cold to the touch.
Typical work covers air in loft panels, seized valves, radiators that stay hot or cold regardless of the setting, gable-wall radiators that never warm their rooms and pins that stick. Horwich households can place each radiator and describe the wind, so a reader can separate air from a seized pin or heat lost to the wall.
With the heating off and the radiator cool, press the valve pin gently and see whether it moves and springs back. Bleed with a cloth beneath the screw and note how much air or water comes out. Photograph the valve and the pipe. Do not hit a stuck pin with a hammer, do not remove a valve head with the system hot and do not leave a bleed screw open. Say how cold the porch gets.
Say when each attic radiator was last bled and how much air came out.
Press the pin when the radiator is cool and say whether it springs back.
Note any radiator that stays hot when its valve is turned off.
Say how cold the gable wall behind a radiator feels.
A house on the upper streets has an attic radiator cold across the top and hissing every week, while a porch radiator stays hot all summer and the gable-wall radiator in the lounge never gets the room warm. They bleed the attic panel and hear air for half a minute, press the porch valve pin and find it stuck down, photograph the valve, note the gable wall behind the lounge radiator feels cold and say the pump hums. A reader sees air in a high panel, a seized valve and a wall that steals the heat.
Air collects. Bleed with a cloth.
Seizing. Press the pin when cool.
Wind-chilled walls. Feel the masonry.
The small spring-loaded rod inside a radiator valve that is pressed by the valve head to open or close the flow.
The little screw high on a radiator that lets trapped air out when it is eased open.
A pocket of air that blocks the flow of water in a pipe or radiator.
Probably air. Note how often and how long the hiss lasts.
Probably the pin. Press it gently when the radiator is cool.
Please not. Photograph the valve and describe how it feels.
It may be the cold wall. Feel the masonry and say how big the room is.
Not by itself. Writing comes before anything else; the decision on a visit waits until you have a quote.
Bleed the attic panel with a cloth, press each valve pin when cool, feel the gable wall and then place your Horwich radiator repair enquiry with Repairco.
Submitting a repair enquiry does not confirm an appointment or payment.