Radiator style
Column, panel or cast iron? Say what you have.
Large rooms and tall houses are hard on radiators, and a failing one is quickly noticed on a winter morning. This guide shows what to say about radiator problems in a Didsbury house, briefly and clearly.
Didsbury's late-Victorian houses have big rooms, high ceilings and radiators to match. Many keep old cast-iron or column radiators, heavy and slow to heat, with large water volumes and valves that have been painted over several times. A column radiator that is cold at the bottom has often accumulated sludge, while one that is cold at the top has air, and the two causes call for different descriptions.
Top-floor rooms are the hardest to heat because the pipes to them are the longest. If an attic bedroom never feels warm, it may simply be the end of a long circuit, or its radiator may be undersized for the volume of the room. Saying how big the room is, and whether the radiator is the same type as elsewhere, helps to judge which of those is more likely.
Typical Didsbury enquiries include column radiators cold at the base, valves that have seized with paint, attic rooms that never reach temperature and radiators that leak at joints. Name the room, the floor and the radiator style, and give the size of the room if you can. A photograph of the radiator with its valves, and one of the room, shows what a description cannot.
Do not force a seized valve, as the spindle can break and cause a leak. Describe it instead: whether it turns a little, not at all or spins freely. If a radiator leaks at a joint, say where and take a photograph. If you have bled it recently, say how much air came out, because that suggests whether trapped air is part of the story.
Column, panel or cast iron? Say what you have.
Note which floor it is on and how far it is from the boiler.
Give approximate dimensions and ceiling height.
Say whether the valve turns freely, stiffly or not at all.
In the attic bedroom of a late-Victorian semi, a panel radiator never gets properly warm, while a column radiator on the first floor is cold at the base. The valve on the attic radiator has been painted over and barely turns. The owner photographs both radiators and valves, estimates the attic room at roughly sixteen square metres under a sloping ceiling and writes that the system was last upgraded about twenty years ago.
Long pipe runs and sloping ceilings. Estimate the floor area.
Tall rooms and heavy radiators. Describe the radiator type.
Column radiators cold at the base. Note the pattern.
A radiator made of vertical tubes joined at the top and bottom, often found in older homes.
A valve whose spindle has stuck, often because of paint, corrosion or years without use.
The amount of heat a radiator gives out, which must suit the size of the room it serves.
Quite possibly. Say how it feels at the top and middle, and whether the other radiators behave the same way.
No. Forcing can break the spindle. Describe how far it turns and photograph the valve.
It may be. Provide the floor area and ceiling height, and note whether the radiator itself gets hot.
Say where it weeps, how much and whether it is only when the heating is on. Photograph the joint.
Say when it was last upgraded and whether radiators are original. Even a rough guess is fine.
Name the radiator style, floor and room size, and describe how the valve moves. A photograph of the radiator and the room puts the whole picture in front of a reviewer, whatever the weather outside is doing. If the radiator was installed or moved recently, give the approximate date, which helps to link a fault to the work.