Tank and cylinder
Say where they are and roughly how old they look.
Thermostatic valves expect balanced pressures, and a large old house rarely supplies them without help. This page explains how to describe a thermostatic shower fault from a Didsbury house where tanks and pumps are part of the story.
Many Didsbury houses still feed their upstairs bathrooms from a tank in the loft and a cylinder in a cupboard, with a pump added to give the shower some force. The hot and cold feeds come from different places and may differ in pressure, which is exactly what a thermostatic valve dislikes. When the balance is wrong, the valve may shut off hot water entirely as a safety measure, leaving a cold shower.
Pumps add their own behaviour. A pump that starts late, runs unevenly or cavitates makes the flow pulse, and the valve then chases the changes. If your shower pulses, describe how fast, and whether you hear the pump. If you know where the pump is and what make it is, say so. Photographs of the pump, the valve and the dial together give a very full picture. A note of how many bathrooms the pump feeds also helps, because shared pumps behave differently from dedicated ones.
Typical Didsbury cases include thermostatic showers that go cold after a minute, that deliver only cold when the cylinder is warm, that pulse in time with a pump or that never reach the set temperature. Describe the arrangement as well as you can: where the tank and the cylinder are, whether a pump is fitted and which bathroom the shower serves.
If other bathrooms in the house behave differently, say so. A top-floor shower is more affected by low pressure than one on the first floor. Say whether the problem is worse at certain times, such as the morning rush when several outlets are in use. A small log of when the fault occurs, kept over a few days, gives a reviewer something firm to work with.
Say where they are and roughly how old they look.
Is a pump fitted? What is its make, and does it hum, pulse or run on?
Note which floor the shower is on, since pressure varies.
Keep a short log of when the shower fails and what else is in use.
Under the roof of a late-Victorian semi, the thermostatic shower runs well for a minute and then switches to cold. The cylinder is hot, and a pump sits in the airing cupboard, humming when the shower is used. The owner photographs the pump, the shower dial and the valve plate, notes that the first-floor shower behaves normally and keeps a three-day log of the times the shower fails.
Lower pressure and added pumps. Describe the pump.
Better pressure but ageing valves. State the shower's age.
Long pipe runs. Note where the pipes come from.
A system where water drops from a high tank and gets its force from the height of that tank.
A small electrical unit that lifts the flow to a shower when natural pressure falls short.
Bubbles forming in water at a pump inlet, causing noise, pulsing and loss of performance.
Often pressure imbalance. Describe the pump, when it starts and whether the downstairs shower is affected.
It could be either. Say how fast it pulses and whether it matches the pump's sound.
Note the time, which taps were in use and how the shower behaved. A few entries over several days are enough.
It does. Say whether it is hot at the time the shower fails, by feeling the pipes near it with care.
Yes, along with the valve and dial. Up to two pictures fit in the quote, so choose the pump and the dial.
Say where the tank, the cylinder and any pump are, keep a short log of failures and photograph the pump and dial. In a tall house those facts reveal how the shower is supplied.
Submitting a repair enquiry does not confirm an appointment or payment.