Board type
Ceramic fuses, a mix of fuses and switches or a modern unit? State what is visible.
Some Didsbury houses still have old fuse boxes beside modern kitchens. When the power goes off in a house like that, the details of the board decide how the fault should be explained. Here is how to do it.
In the late-Victorian houses around Albert Park, a consumer unit may be tucked beneath the staircase, down in a cellar or by the meter in a porch. Older houses may still have a ceramic fuse board with rewirable fuse carriers, while others have switch-based units added in various decades. A house can even have more than one, because extensions and conversions were often given their own supply points.
Large houses make partial failures common. The first floor can lose power while the ground floor stays on, or the loft rooms can go dark while the kitchen is unaffected. Because lights and sockets are usually on separate circuits, losing one but not the other is a significant clue. Say exactly which parts of the house are affected, floor by floor, before anything else.
Typical Didsbury cases are blown fuses that blow again as soon as they are replaced, switches that trip when a particular appliance runs, upstairs floors without power, and boards that make a humming sound. Describe the board type, what you see and what happened just before the fault. Please do not replace or fiddle with fuses yourself if they keep failing.
If there is any smell of burning, visible scorching or a noise from the board, keep away and call 999 if you see smoke. Otherwise, photograph the board with its cover closed, and, if the cover is a clear window, what is visible through it. Write down the colour and number of fuses or switches if they are labelled, since that helps identify the board.
Ceramic fuses, a mix of fuses and switches or a modern unit? State what is visible.
List which floors have power and which do not.
If a fuse keeps blowing, note how soon and what was switched on at the time.
Is there more than one board in the house? Say where each sits.
On a cold evening, a family in a late-Victorian semi finds the first-floor lights dead while the ground floor is on. The old board under the stairs has ceramic fuse carriers, and one of them looks blackened. They leave it untouched, photograph the closed board with a torch, write down which rooms are affected, note that a heater was running in the front bedroom when the lights went out and add that the board is original to the house.
A very common place for old boards. Photograph from a short distance.
Damp-prone boards and meters. Mention any condensation.
Boards beside the meter. Note any extra units nearby.
A fuse made from a short length of wire held in a carrier that must be replaced by hand when it blows.
The thick cables that connect the electricity meter to the consumer unit.
A path of cable that carries power from the board to a group of lights or sockets.
Say that the whole upper floor is out and that downstairs works, and what was running when it failed. Photograph the closed board.
Something on that circuit is drawing too much or has a fault. Stop replacing it and describe what is connected.
A hum should be reported. Keep away, note when it started and call 999 if there is a burning smell or smoke.
It helps to say so. Describe where each is and which part of the house each seems to feed.
If they are easy to see, yes. Photograph them from a distance and write down what you can read, without touching.
List which floors have power, describe the board with its cover closed and say what was running when it failed. For an older house, that account is more useful than a diagnosis.