Name each board
Call them house, garage or annexe, and photograph each with its label.
A large house may have two or three boards and several outbuilding supplies, which makes it more important to say which part has failed. Here is how to report a power loss in a Worsley home.
Larger Worsley houses often have a main board near the meter, a second in a garage or utility room and a third feeding an annexe, workshop or garden room. Each protects different circuits, and a trip in one may leave parts of the house in the dark that seem unconnected. Labelling matters: a board whose labels have faded, or whose circuits were never named, is a puzzle even to the owner.
Outbuilding supplies run underground or overhead from the house, and they can suffer from damp, damage from digging and frost. If a garage or garden room loses power while the house is fine, say so, along with when the cable was last disturbed, whether work has been done nearby and whether a switch at the house end has dropped. A smart meter or a solar installation may also be involved, so mention either one. If you have a generator or a battery backup, say how it is connected and whether it switched on during the outage, because changeover equipment can itself cause a loss of power.
Power loss and board faults include tripping circuits across multiple boards, outbuildings that go dark, labels that do not match circuits, supplies from solar or batteries that confuse a board and humming units. Worsley residents can name each board, describe what it feeds and say what failed.
Give each board a name, such as house, garage or annexe, and photograph each with its label. Note which switches have dropped. If a solar inverter or battery is fitted, say what it shows. For an outbuilding, say how the supply reaches it and whether the ground above has been disturbed. If a power cut affects the area, call 105. Do not dig along cable routes to look for faults.
Call them house, garage or annexe, and photograph each with its label.
Say how the supply reaches the outbuilding and whether the ground was disturbed.
Mention any inverter or battery and what its display shows.
If labels are missing or wrong, say so. It helps a reader plan.
In a large house, the garden room loses power during a storm while the main house is fine. The owner names the three boards, checks the garage one, finds a switch down labelled only with a faded number and photographs it. They note that a new patio was laid last spring over the cable route and that the solar inverter shows a fault light. The enquiry is organised by board and by route.
Secondary boards with faded labels. Photograph the label.
Underground cables. Say whether the ground was disturbed.
Inverters and batteries. Report what the display shows.
A smaller distribution board fed from the main one, often in a garage or outbuilding.
A device that converts the direct current from solar panels into the alternating current used in a house.
A cable with a metal sheath, often used underground to feed an outbuilding.
Which board feeds it, which switch dropped, how the cable runs and whether the ground has been disturbed.
It can matter. Take a picture of the screen and record when the light first showed and whether the trip coincided with it.
Photograph them as they are and say so. A reader needs to know that labels cannot be trusted.
Very. Say where it lies and when it was done, as disturbed ground is a common source of cable faults.
Use 105 and write down the reference. Mention it in your enquiry so a reader does not hunt for a fault in the house.
Name each board, photograph the labels and note any solar equipment or ground disturbance. Then send your Worsley board and power loss enquiry.
Submitting a repair enquiry does not confirm an appointment or payment.