Whole or part
Say whether the whole house lost power or only some rooms.
When the lights go out in a Failsworth house, the cause may lie in a board older than anyone living there, in a damp cellar where the meter sits, or in a cupboard on a mill landing that serves several flats. Power faults are easier to read when the place is described first.
The 1930s semis along the main road often still have a board of porcelain fuse holders, or an early metal box, fitted when the house was wired and added to ever since. Fuses of different ratings sit in the same board, and a wire that has blown is sometimes replaced with something thicker. Say what the board looks like, whether it uses wire fuses or switches, how many circuits there are, whether anything has been added to it and whether fuses blow often.
Terraces beside the canal have cellars where the meter and board sit low on a damp wall. Moisture settling on a board can cause trips whenever the weather turns wet. In mill flats the board may sit in a shared cupboard with others, and the main switch may serve more than one home. Record where the board is, whether the wall is damp, whether a neighbour's supply failed with yours, who keeps the cupboard key and whether the landlord manages the supply. If a neighbour's flat shows the same trips at the same hour, say so, because a shared fault at a riser or meter cupboard needs the owner of the building as well as you.
Distribution board and power loss work in Failsworth covers old fuse boxes, tripping breakers, dead rooms, flickering supplies in wet weather and shared boards in flats. The first question for a reader is whether the whole building lost power or only part of it, because a street-wide cut belongs to the network and a part-house loss belongs to the board.
Look at the board with the lid closed and note which switches or fuses are down. Photograph it open only if the cover is safe to lift without tools, and never reach inside. Check whether the neighbours have power. For an outage across the area, call 105. Do not replace a blown fuse with a larger wire, do not reset a switch that immediately trips again and do not use a board in a wet cellar.
Say whether the whole house lost power or only some rooms.
Ask whether next door or the flat beside yours lost power too.
Note any damp, rust or drips on or beside the board.
Say how often fuses blow and whether anyone has replaced the wire.
In a 1930s semi the ground floor loses power each evening when the kettle and the oven run together, and the cellar board is a wooden box of wire fuses set against a damp wall. The household notes next door is unaffected, photographs the closed board and the damp patch, writes down that the kitchen fuse has blown three times this month and records the time of each loss. A reader sees an overloaded circuit on an old board in a cellar that is damp.
Blown fuses. Log the dates.
Damp-day tripping. Note the wall.
One main switch. Ask the neighbours.
A thin wire or cartridge that melts to cut off power when a circuit carries too much current.
The large switch on a board that turns off all the power in a home.
A loss of supply that affects a street or area, handled by the network operator.
Possibly overloaded. Log the times and note what was running.
Yes, damp and electricity do not mix. Stand back and photograph it from the doorway.
Please not; a thicker wire defeats the protection. Describe the fuse holder.
Check neighbours first, then dial 105 for the network.
Answers are in writing; visits follow a quote you have accepted.
Check the neighbours, note which fuses are down, snap the shut board and the damp patch, and then send your Failsworth power details to Repairco.
Submitting a repair enquiry does not confirm an appointment or payment.