In many Radcliffe terraces the electricity supply arrives in a cupboard by the front door, beside a board that has served since before anyone living there was born. When a circuit trips after rain, the old board is not always the culprit; the damp wall often is.
A terrace hallway often holds the meter, the cut-out and a small board with rewireable fuses or a few breakers, mounted on a damp-prone party wall. Moisture reaching the back of the board corrodes terminals and trips circuits on wet days. Say what the board looks like, whether the wall is damp, whether a smell of hot plastic is ever noticed, whether the fuses blow more in wet weather and whether the cover is rusty.
Power loss to a room in a terrace may come from a joint behind plaster that has been getting damp for years, or from a cable that crosses the cellar wall. Lights may flicker on wet mornings and recover by afternoon. Say which rooms lose power, whether sockets and lights fail together, whether the loss occurs after rain and whether the cellar or the cupboard under the stairs is damp.
Typical work includes finding trips that follow the weather, replacing old fuse boards, testing circuits that have gone dead and tracing damp-affected joints. The pattern over days and weeks matters more here than a single event, so a reader needs a log tying each loss to conditions outside.
Look at the board without opening it, photograph its front and the wall around it, and write the dates and weather for each trip. Note which circuits go first. Do not wipe a damp board with a cloth, do not wedge a breaker on, do not replace a blown fuse with wire of a heavier gauge and do not store items against the cupboard wall. Say whether the board's cover is rusted or the paint is blistered. Also say how long the damp has been present, whether the hall has been replastered recently and whether a dehumidifier has been used nearby, because the history of the wall helps a reader understand how long moisture has been working on the terminals.
Write the dates of each trip against rain, fog or cold.
Photograph the wall around the board and note any damp, rust or blistering paint.
Say which circuits trip first and whether lights and sockets go together.
Say whether the cellar or under-stair space is damp or musty.
By the front door of a mill terrace, a household finds the downstairs sockets dead on three wet mornings in a row and the board cover freckled with rust. They photograph the board front and the damp wall behind the coats, log the dates against the rain, note the lights stay on and say the cellar smells earthy. A reader sees moisture reaching a joint or the board itself on wet days, and a circuit that recovers as the day dries.
Rust and damp. Photograph the wall.
Weather-linked failures. Log the dates.
Cellar damp nearby. Note the smell.
The main fuse where the electricity supply enters a building, usually beside the meter.
An older type of fuse in which a thin wire is replaced after it blows.
A metal connection point in a board where a cable end is clamped.
Possibly both. Photograph the wall and log the weather.
It can suggest moisture. Photograph it with the front closed.
Please not. Heavier wire removes the protection. Write out the pattern.
Please do not touch it. Photograph the wall instead.
The form brings nobody to the door. Replies reach you in writing first, and nobody visits unless you accept a quote.
Photograph the board front and the wall behind, log each trip against the weather, note which circuits fail first and then write up your Radcliffe distribution board enquiry for Repairco.