Which switch
Name the switch by its label, or photograph its position in the closed unit.
If a switch in your consumer unit trips every time the oven and dishwasher run together, you are looking at a pattern, and a pattern is the most valuable thing you can report. This page explains how.
Chorlton households often cook, clean and charge at the same time, and the kitchens added to many Edwardian and interwar houses run several heavy appliances together. When a circuit trips under that load, the cause may be an overloaded circuit, a faulty appliance or a leak of current to earth. The first thing to record is what was running when the switch moved.
There is also the question of which kind of switch tripped. Modern units have two kinds: small breakers that protect against overload and a residual current device that reacts to leakage. A trip with the kettle on is a different story from one that happens when it rains or when the garden lights come on, and noting the weather and the time of day gives a reviewer a firm place to start.
Typical Chorlton enquiries describe switches that trip with the oven and hob, circuits that will not reset after a storm, extension circuits that lose power when a heater is used and units that click or hum. Say which switch tripped and what was running. Avoid switching things on and off repeatedly to test them, since that can make a fault worse.
If you notice a smell of burning, a hot cover or crackling at the unit, step away, and dial 999 should smoke appear. For ordinary trips, unplug the appliances on the affected circuit, try the switch once and report what happened. If it holds, plug appliances back one by one and note which one brings the trip back; that tells the reviewer a lot.
Name the switch by its label, or photograph its position in the closed unit.
List appliances running when it tripped, in order.
Does it happen in rain, at night or after the garden lights come on?
After unplugging, plug devices back one at a time and note which trips it.
Near Beech Road, in an Edwardian terrace, the kitchen circuit trips whenever the oven, the dishwasher and the kettle are all in use. The owner unplugs everything, resets the switch once, plugs the devices back in one at a time and finds that the trip returns only when the dishwasher starts its heating cycle. They photograph the closed unit with the tripped switch visible, write down the sequence and note the age of the dishwasher.
Heavy loads on one circuit. Note combinations that trip it.
Circuits shared with outside lights. Mention weather links.
Tool use on small circuits. Name the tools.
A small switch that protects a circuit by tripping when it carries too much current.
A small flow of current to earth where there should be none, often from a faulty appliance or damp.
The part of an appliance's programme when its heating element is on, drawing the most power.
Maybe, but it may also be one appliance. Run the one-by-one test and report which device brings the trip back.
Possibly moisture in an outdoor fitting or appliance. Note the weather and which outside lights or sockets are in use.
Try it once, not repeatedly. Frequent resets can make a fault worse. Describe what happened instead.
Some click is normal, but report loud or repeated clicking, any heat and any smell, and do not open the unit.
Look for labels. If there are none, photograph the unit and describe the position of the switch that trips.
List the appliances that were on, note whether weather or time of day plays a part and describe the switch that tripped. A one-by-one test gives a reviewer something to work with.
Submitting a repair enquiry does not confirm an appointment or payment.