Run log
Write down warm-up time, cut-outs and spray changes over a week.
An electric shower heats the water as it passes through, and in Failsworth the water is hard, the pipes are old and the cord that switches the unit on hangs from ceilings that hold moisture. Each of those leaves a different mark on how the shower behaves.
Hard water coats the heating element inside an electric shower with scale, which makes it less efficient and more likely to trip. The shower may run lukewarm, cut out part-way or give a weak, uneven spray. Give the unit's age, say whether it trips the breaker or only its own safety switch, whether the temperature has dropped over the year, whether the spray has changed and whether the kettle in the house furs up quickly. A photograph of the unit's label, which lists its power rating in kilowatts, tells a reader how heavy a load the supply must carry.
A pull-cord isolator on a damp canal-side ceiling can corrode inside its housing, and in a mill flat a compact shower sits on a thin partition with a short cable run from the board. Describe where the isolator is, whether its cord is frayed or sticky, whether the ceiling above is stained, whether the unit is fixed to board or to brick and whether the supply cable runs on the surface or inside the wall. Say too who looks after the cubicle, since a shower in a mill-conversion flat may belong to the landlord.
Electric shower work in Failsworth covers units that run lukewarm, trip the board or cut out, scaled elements and heads, weak spray and isolators that stick. A reader helps by saying what the shower does and when, since a unit that trips every time it starts points to a different cause from one that fades after a few minutes.
Run the shower and write down what happens: how long to warm, whether it cuts out and whether the spray weakens. Photograph the unit's face, the head and the isolator without opening anything. Keep the cover on the unit, stop using a shower whose casing is cracked or wet inside and avoid resetting the breaker over and over.
Write down warm-up time, cut-outs and spray changes over a week.
Say whether the breaker at the board or the unit's own switch trips.
Photograph the pull-cord, its housing and any stain on the ceiling.
Look for cracks or water marks on the unit's outside.
In a 1930s semi the electric shower over the bath runs lukewarm and cuts out after two minutes, the spray is uneven and the pull-cord is sticky with damp. The household keeps a log of warm-ups and cut-outs for a week, notes a thick coat of scale in the kettle, photographs the unit's face and the cord, spots the stained ceiling above and records that the board's breaker never tripped. A reader sees a scaled element, a damp isolator and a unit that is stopping itself.
Scaled elements. Log the cut-outs.
Damp ceilings. Photograph the cord.
Thin partitions. Note the wall.
A ceiling pull-cord or wall switch that cuts a shower's power so that work on it is safe.
The part inside an electric shower that heats the water as it flows past.
A device that lets the element heat only when water is moving.
Scale on the element is possible. Log the warm-up and the cut-outs.
That can be so. Turn the power off at the board, then photograph the cord and the stain.
Please not; the unit carries mains power. Describe what you can see outside.
It can. Say how furred the kettle is and how old the unit is.
Written words come first; attendance follows a quote you accept.
Log the warm-up and the cut-outs, photograph the cord and the stain without opening anything, then give Repairco your Failsworth shower details.
Submitting a repair enquiry does not confirm an appointment or payment.