Minimum flow
Many units need a minimum flow to start. Test the cold tap beside it.
Electric showers need steady water flow to work, and in Stockport that is not always on offer. Hills, tall terraces and shared mill plumbing can all starve a unit of the flow it needs.
Houses high on the slopes sometimes see low mains pressure, and an electric shower that needs a minimum flow to switch on may refuse to start or may cut out partway. Terraces with a shower added in a back bedroom over a stair may have a long run of pipe that loses pressure. Say how high the house stands, whether the flow is weak in the kitchen too and how the shower behaves when others use water. Electric showers are normally fed from the mains, so say whether yours is, because a tank-fed supply is usually too weak for one.
Mill flats with small bathrooms often use compact electric units, fed from a shared riser, with hard water causing scale on the spray plate. Shared supplies can drop in pressure when neighbours draw water, causing the heater to cut out. Say what the unit's label says, whether neighbours report the same issue and whether crusting is visible on the spray plate or round the controls.
Typical issues include showers that will not start at busy times, units that trip the supply, heads blocked with scale, leaks round the casing and pull cords that fail. Stockport households can describe the height, the supply and the time of day, so a reader can see whether the water, the unit or the circuit is likelier.
Run the kitchen cold tap fully and note how strongly it flows, then compare with the shower. Photograph the unit, its label and the scaled head. Ask neighbours whether their showers weaken at busy times. Isolate the unit at the pull cord before inspecting. Do not open the casing and do not drill through a tiled wall to check the pipes. Take notes at the same times on two or three days, as a single reading can mislead when demand varies from hour to hour.
Many units need a minimum flow to start. Test the cold tap beside it.
If it fails at peak times, shared demand may be lowering pressure.
A crusted spray plate lowers flow. Photograph it.
Ask whether the shower weakens when neighbours draw water.
In a mill flat, the electric shower refuses to start at seven in the morning but works at noon. The household runs the cold tap at the basin and notes a thin flow at seven, photographs the unit's label and the scaled head, asks the neighbour on the floor above who reports the same, and says the unit is five years old. They also record that the cold tap was normal at noon and that the unit gives no fault light. A reader sees a pressure issue at peak demand, with scale as a second factor.
Minimum flow limits. Test the cold tap.
Long pipe runs. Note the height.
Shared risers. Ask neighbours.
The lowest water flow at which an electric shower will switch on its heater.
The perforated face of a shower head through which water leaves in streams.
A vertical pipe carrying water up through the floors of a building.
Flow may fall below its minimum. Compare it with the basin tap and ask neighbours.
It often does. Name the product and note any change in flow.
Probably not. Describe flows at other taps and the time of day.
A larger unit may need a bigger cable. Say the present rating and ask a reader first.
Not by itself. A reader looks first, and a visit would follow only a quote you accept.
Compare the cold-tap flow with the shower, photograph the label and scaled head, ask neighbours about peak times and put the Stockport shower enquiry to Repairco.
Submitting a repair enquiry does not confirm an appointment or payment.