Cold tap flow
Check the cold tap in the same bathroom. Weak flow suggests a supply issue.
Apartment bathrooms are compact, and an electric shower with its ceiling isolator takes a good part of the wall. Below is a guide to describing a fault in one in a Salford flat or converted home.
In apartments around Salford Quays and MediaCityUK, an electric shower is often chosen for flats where hot-water supply is limited, or where a second shower is wanted. The unit is fixed to the tiled wall, fed from a dedicated circuit with an isolating switch in the ceiling. A fault may therefore lie in the unit, in the water supply, in the isolator or in the circuit in the consumer unit.
In managed blocks, the water supply to individual flats may run through shared pipes, and any works that need the supply shut off must be coordinated with the managing agent. If the shower has stopped working and the cold tap in the same bathroom is weak, say so, because that suggests a water supply issue and not the shower itself. That distinction matters a great deal.
Typical Salford enquiries describe electric showers that do not start, that trip the supply, that dribble, that run cold on the higher setting and whose isolator cords no longer click. Describe the unit's lights and sounds, say how old it is and note the rating from its label. Photograph the unit and the isolator from a distance. Do not remove covers.
Check whether the cold tap in the same bathroom has normal flow. If it is weak, the shower may be starved. Check also whether the ceiling isolator is switched on, and say what its indicator does. If the building has had recent water works, mention them. A short timeline of what happened and when is the most helpful thing you can send.
Check the cold tap in the same bathroom. Weak flow suggests a supply issue.
Is the ceiling switch on, and does its light show?
Does it start, heat, fade or trip? Describe the sequence.
Say if there have been water or electrical works in the block.
In a quayside flat, the electric shower in the second bathroom no longer starts. The ceiling isolator is on and its light glows, the unit's power light is dark and the cold tap in the basin runs weakly. The owner photographs the unit, the isolator and the dark light, notes the rating from the label, writes that the building had water works last week and says the flat is on the fifth floor.
Electric units beside basins. Test the cold tap too.
Supply disturbed by works. Mention any dates.
Units on older circuits. Note the cable and switch.
A switch fixed to a ceiling, operated by a cord, that cuts the supply to a fixed appliance such as a shower.
The force with which water is pushed through the pipes, which can affect how well a shower works.
A water supply too weak to provide the flow that an appliance needs.
The supply may be fine and the unit or the water flow at fault. Say what the unit's lights show and whether the cold tap is weak.
Yes, by disturbing the supply. Mention any dates of water works and whether neighbours had issues.
It may be. Describe how it feels, whether its light changes and whether the shower responds to it.
Normally the building's managers. Mention it, since works may need to be coordinated.
Better to switch it off at the cord until the problem is understood, and say that you have done so.
Check the cold tap, note what the isolator and unit lights show and mention any building works. Pictures of the unit and the isolator make the account complete and safe, and a note of the floor adds context. Mention the make of the unit as well, if it is printed clearly on the front panel.