Time of day
Report the worst time of day. Peak-time pressure drops often explain poor heat.
Many Swinton families added an electric shower to avoid queueing for the main bathroom. Below is how a fault in one is best reported, so the circuit as well as the unit is understood.
Semis off Chorley Road often have a second shower in an extension, a converted bedroom or a small cloakroom downstairs, powered by a unit on its own cable from the board. Because the shower was added later, the cable run may be long and the circuit may share a board with older wiring. A unit that works at first and then cuts out may be overheating or tripping a protective device, and the age of the installation matters.
Water supply to these showers is often a branch off the mains, with a long run of small pipe. A drop in mains pressure at peak times can leave the unit unable to heat enough water, so it delivers a trickle at a modest temperature. Say what time of day it is worst, whether the kitchen tap is also weak then and whether the pressure was ever better.
Electric shower repairs include units that cut out partway, trip the circuit, heat poorly, spray unevenly, leak from the casing and cut off when the water pressure drops. Swinton households can say what the shower does at each setting, how it is wired and who installed it, and a reader can judge whether the fault lies in the unit, the supply or the circuit.
Record the make, rating and age from the label. Note the time of day when it is worst. Check whether the shower works on cold water only. Photograph the unit, the cable entry and the isolator. Say whether the board has a dedicated switch labelled for the shower. If the unit leaks from its casing or the cable looks warm, turn off the isolator and the board and leave it alone.
Report the worst time of day. Peak-time pressure drops often explain poor heat.
Say whether the board has its own switch for the shower, and photograph it.
Look at where the cable enters the unit. Warmth or marks are worth reporting.
Say whether it delivers cold water normally. A cold-only fault points to the heater.
In a semi off Chorley Road, the downstairs shower in a converted utility room cuts out after two minutes and then needs a minute before it restarts. The owner notes that it is worst on school mornings, finds the kitchen tap also weak then, photographs the label showing eight and a half kilowatts and the dedicated switch on the board, and writes that the unit was installed during an extension about ten years ago. The pattern points toward pressure and thermal cut-out.
Long cable runs. Say how far the unit is from the board.
Branch pipes with low pressure. Note peak-time weakness.
Small rooms with condensation. Photograph the casing.
A safety device inside the unit that switches off the heater if the water becomes too hot.
A cable and switch at the board that supply a single appliance alone.
The force of water in the supply pipes, which can fall when many people use water at once.
The time of day, whether the kitchen tap is weak then, the rating on the label and whether it restarts after a pause.
Look for a switch labelled shower or a high amp rating beside the cooker's. Photograph the board without opening it.
No. Switch off at the isolator and board, and photograph the leak and where the water runs.
It can. Say roughly how far the unit is from the board, as long runs need heavier cable.
Yes, with the power off. Say whether the water flows normally, which separates the supply from the heater.
Note the time of day it fails, read the label and photograph the unit, isolator and board switch. Then send your Swinton electric shower enquiry.