Rating label
Photograph the label and note the power rating if it can be read.
An electric shower was often the first luxury added to a Bolton terrace, fitted to an old fuse board on a cable run chosen for convenience. Twenty years on, the faults a reader hears about are trips, cold spells and thin spray.
Terraces and villas gained showers above baths long after they were wired, and the unit draws a large current from a board that may be decades old. A shower that trips the board, hums or runs only on a low setting can be asking more of the circuit than it can give. Locate the board and judge its age, name the switch the shower has, then add whether other things trip when it runs and how many years the unit has been in place.
Showers in mill flats and rear extensions often run from a pull-cord isolator on the ceiling with a cable hidden in the wall. Deposits narrow the spray plate, and a unit that clicks and runs cold may have a tired element or a pressure switch that no longer closes. Say how the spray looks, whether it is evenly spread, whether the temperature fades after a minute, whether the unit clicks and where the pull cord sits.
Electric shower work covers cold running, trips, thin or sideways spray, clicking units, heads that clog and switches that feel warm. In Bolton the age of the unit and the board are usually known, which lets a reader weigh a scaled element, a blocked head, a worn switch and an overloaded circuit.
Switch the shower off at the wall before looking closely. Take pictures of the head, the spray plate and the unit's label showing its power rating. Note the temperature and spray pattern at each setting. Do not take the cover off the unit, do not poke the spray holes with a pin while it is switched on and do not use a shower whose switch smells hot. Leave a tripping circuit off and say so.
Photograph the label and note the power rating if it can be read.
Say whether the shower's own switch or the whole board trips.
Describe whether the spray is even, thin or pointing sideways.
Note any heat or smell from the isolator or pull cord.
In a terrace, a household finds the electric shower runs cold after a minute and trips the board when the kitchen kettle is on, while the pull cord feels warm and the spray comes out sideways. They switch the shower off at the wall, photograph the label and the spray plate with its chalky edge, note the board is a fuse box with ceramic holders, say the cord was replaced a few years ago and mention a faint smell near the switch. A reader sees a scaled head, an overloaded circuit and a switch to be left alone.
Trips and heat. Read the label.
Warm cords. Switch off first.
Shared loads. List what else runs.
The amount of electricity a shower draws, printed on its label in kilowatts, which sets the cable and the breaker it needs.
A switch, often a ceiling pull cord, that cuts power to a fixed appliance without using the board.
The holed face of a shower head where the water leaves, which deposits can clog.
Perhaps. Switch it off, photograph the label and say what else was running.
Please not. Leave it off at the board and say so.
Only with the power off and the shower dry. Describe the pattern first.
No. Describe the click and when it happens.
Nobody is despatched because of it. The answer comes in writing; attendance follows a quote that you accept.
Switch off at the wall, photograph the label and spray plate, note what trips and then place your Bolton electric shower enquiry with Repairco.
Submitting a repair enquiry does not confirm an appointment or payment.