REPAIRCO / HEATING / ECCLES

Electric shower repairs in Eccles, for units that trip the board, run cold or click without heating

An electric shower is a simple machine with a powerful heater inside, and when it fails, the symptoms narrow the cause quickly. An Eccles household can help by saying exactly what the unit does when it is switched on.

Call 0161 840 0020
LOCAL CONTEXT

Electric shower repairs around Eccles.

Many Eccles terraces have no mains-fed shower from the boiler, so an electric unit was fitted over the bath or in a converted corner, run from a cable and a cold water pipe. These units heat water as it passes over an element, using eight to ten kilowatts, which is as much as a cooker ring. Over years the element scales up, the flow switch sticks and the cable and isolator behind it take a hard life.

Because the load is heavy, the cable, the pull-cord switch and the board circuit must all be in good condition. In older houses, wiring may be thin or over-run by later additions, and a shower on a shared circuit may trip when a kettle or heater joins it. A unit that clicks but gives no heat, or one that trips the board only on its hottest setting, tells a reader a lot about where the weakness lies.

THE WORK

What this repair involves.

Electric shower repairs cover units that will not switch on, trip the board, heat only slightly, run hot and cold in bursts, dribble and click, leak from the casing or give an electric tingle. Eccles residents can describe the behaviour on each setting, the age and rating of the unit and what else was running, and a reader can narrow the cause.

Note the kilowatt rating on the label, the make and the age. Try each power setting and record what happens. Check whether the isolating pull-cord light comes on, and whether the board has a switch down. If the casing leaks, or you feel any tingle, stop using it, turn off the pull-cord and the board and say so. Never open the cover or reset the board repeatedly. Photograph the label and the unit. Mention too whether the water supply to the unit has a small tap or valve on it, since a half-closed valve is a surprisingly common reason for a shower that clicks without heating.

BEFORE YOU ENQUIRE

Four clues from an electric shower

Power setting

Say how it behaves on low, medium and high. A fault only on high points to the element or the circuit.

Clicking or tripping

A click without heat suggests a stuck flow switch. A board trip points to the element or wiring.

Rating and age

Read the kilowatt figure on the label and say how old the unit is.

Tingle or leak

Any tingle or water inside the casing means stopping use and switching off both supplies.

A TYPICAL CASE

How it can look in a Eccles home.

In an old brick terrace, the electric shower over the bath clicks when switched on but only delivers cold water, even on the hottest setting. The owner notes the label says nine kilowatts, tries each setting with the same result, checks that the pull-cord light is on and the board has no tripped switch, photographs the label and says the unit is fifteen years old. They add that water has become less strong lately. A reader suspects a clogged inlet and a stuck flow switch.

AROUND ECCLES

Eccles bathrooms with electric showers

Over-bath units in older terraces

Heavy load on old wiring. Note the kilowatt rating.

Corner cubicles in converted rooms

Added cables and pipes. Say where the supply runs.

Units sharing circuits

Trips when other appliances run. Name them.

GOOD TO KNOW

Electric shower terms made plain

Heating element

The component in an electric shower that heats the water streaming past it, drawing a large current.

Flow switch

A device inside the unit that turns on the heater only when enough water is moving through.

Pull-cord isolator

A ceiling-mounted switch with a hanging cord that isolates a fixed appliance such as a shower.

QUESTIONS

Questions about electric shower repairs in Eccles.

Our Eccles electric shower clicks but runs cold. Which part is suspect?

A flow switch that does not engage, perhaps from a blocked inlet. Say how strong the water is and how old the unit is.

The shower trips the board on the hottest setting only. Why?

The element may draw more current than the circuit allows. Report the rating and what else was running.

I felt a slight tingle. What is the safe response?

Stop using it, turn off the pull-cord and the board, and report exactly what you felt and where.

Can I clear the scale from the head?

A scaled head is common. Note what you did, and keep the casing closed at all times.

How much does the unit's age count?

A good deal. Elements and seals wear over time, so state the age and read the rating off the label.

YOUR NEXT STEP

Describe the problem and review the options.

Read the rating label, try each setting and photograph the unit and the pull-cord. Then send your Eccles electric shower enquiry.

Call 0161 840 0020
Submitting a repair enquiry does not confirm an appointment or payment.