Type and age
Say whether it is a storage heater, panel or fan heater, and give the make and age if known.
Where gas heating is missing or has failed, an electric heater carries the winter, and a fault is felt quickly. Below is a way to report an electric heater problem from an Eccles home.
Plenty of Eccles houses and flats use electric heaters, whether as the main source of warmth or to top up a room the boiler cannot reach. Storage heaters in older flats charge overnight on cheap-rate power and release heat during the day, and their controls are often confusing. A heater that stays cold may be waiting for a charge that never arrives, or its input and output dials may be set in a way that wastes the night's energy.
Wall-mounted panel heaters and convectors are simpler but have their own faults. Thermostats click and fail, elements weaken, fans clog with dust and cables overheat when a plug is loose. An older heater that smells of burning dust in the first cold days is common, but one that smells of hot plastic or trips the board is not. Describe how old the heater is, where it sits and what exactly it does.
Electric heater faults include storage heaters that never warm, panels that click on and off, fan heaters that blow cold, thermostats that stick, towel rails that fail and units that trip the circuit. Anyone in Eccles can name the type, the room and the symptom, and a reader can often tell whether the control or the heating element is at fault.
Write down the make, the model and the age if the label shows them. Note what the controls are set to, whether any indicator light is on and what happens at each setting. For a storage heater, say whether it feels warm in the evening after a night of charging. For a panel, say whether it clicks and whether the wall plate or plug feels hot. Never open a heater, and unplug anything that smells of burning.
Say whether it is a storage heater, panel or fan heater, and give the make and age if known.
Photograph the input and output controls on a storage heater. Mistaken settings are a common cause.
Note any indicator light and whether the unit clicks on and off repeatedly.
A hot plug or wall plate means stopping use and reporting it.
In an older Eccles flat, the owner's two storage heaters have barely warmed all week. They photograph the dials, notice that the input control on one is set very low, adjust it, wait a day and see little change. They check the label for the make, note the heaters are about twenty years old, and write that the switch on the board for the cheap-rate supply was found in the off position. A reader sees two plausible causes laid out.
Overnight charging. Photograph the dials.
Clicking thermostats. Note any hot plate or smell.
Fan units and leads. Say what is plugged in where.
A heater with bricks or blocks inside that heat overnight on cheap power and release warmth during the day.
The dial on a storage heater that decides how much heat is stored overnight.
A device that senses temperature and switches a heater on or off to hold a set level.
Photograph the dials, check the board switch for the cheap-rate supply and say how old the heaters are.
A little is normal, but frequent clicking may be a failing thermostat. Say how often and what the room temperature is.
Switch it off, unplug it and photograph the plug and socket. Do not use it again until looked at.
Only when it is unplugged and cool, and on the outside grille. Never open the casing.
Yes. Storage heaters often depend on a separate supply, so say whether that switch is on and what the meter shows.
Say what type of heater it is, photograph the dials and plug and note any switch on the board. Then send your Eccles electric heater enquiry.
Submitting a repair enquiry does not confirm an appointment or payment.