Water level
Near the brim suggests a stuck valve. Very low suggests a blocked inlet or an empty system.
The tank in the roof does its job quietly for years, then fails all at once. Below is a method for reporting a loft tank fault from an Eccles house, including what to check without climbing into the roof.
Plenty of Eccles houses still hold a cold-water storage tank in the loft, a legacy of the days when mains pressure could not be trusted to reach upstairs. Older tanks were galvanised steel or asbestos-free fibre, and newer ones are plastic, usually with a lid and a small overflow pipe poking through the eaves. The part most likely to give trouble is the float valve, a simple arm and ball that rises with the water and closes the inlet.
A valve that sticks open keeps feeding the tank until it overflows, usually into the overflow pipe, where a steady drip from the outside wall is the sign. A valve that sticks shut leaves the tank empty and the taps upstairs weak. A cracked lid lets dust and sometimes insects in, and a tank that has been neglected for decades may hold sediment that clouds the water. Describe what you see from the hatch and what you notice at the taps.
Water tank repair covers valves that jam, overflows that run, tanks that split or sag on their supports, lids that are missing or broken, sediment in the water and stains on ceilings below the tank. Eccles households can look from the hatch, listen for running water and describe what they find without stepping onto unboarded joists.
Stand on a stable ladder and look through the hatch only. Is the water near the brim? Is the arm of the float valve at the top of its travel, or hanging low? Can you hear a trickle? From outside, check whether the overflow pipe is dripping. Photograph the tank and the lid. If the loft floor is not boarded, do not climb in, since stepping between joists can put a foot through a ceiling.
Near the brim suggests a stuck valve. Very low suggests a blocked inlet or an empty system.
Note whether the arm sits high or low. A bent arm often explains a valve that never closes.
A steady drip from the overflow pipe on an outside wall confirms the tank is overfilling.
Say whether the lid is intact and whether the water looks clear or cloudy.
Late one evening the owner of a brick terrace notices a steady drip from the pipe under the back eaves. They climb a ladder to the hatch, shine a torch and see the water within a finger of the brim, the float arm hard against the top. They photograph the tank and the arm, record the drip outside with a short clip and write that the tank was last replaced decades ago. The reader sees an overfilling tank at a glance.
Joists with no floor. Look from the hatch only.
Drips outside confirm an overflow. Film the drip.
Rust at seams and sagging bases. Photograph the underside if visible.
A valve with a floating ball on an arm that closes the inlet when a tank is full.
A pipe leading outside from near the top of a tank that carries away surplus water.
A steel tank with a zinc finish, often found in old roof spaces and liable to corrode along its joins.
Very likely the overflow. Film the drip and look from the hatch to see whether the water is near the brim.
Only if the floor is boarded. Otherwise look from the hatch, since stepping off the joists can break a ceiling.
Yes. Check the level from the hatch and say whether the downstairs taps are normal.
A gentle adjustment is common, but say what you did, so a reader knows whether the valve still shuts off.
It lets dust and insects in, so report it with a photograph and say whether the water looks clean. Mention whether the tank has ever been cleaned, since old sediment can foul taps and is worth recording.
Look from the hatch, film any overflow drip and photograph the float arm and the lid. Then send your Eccles tank enquiry with those findings.
Submitting a repair enquiry does not confirm an appointment or payment.