Minute-by-minute log
Note the temperature each minute for five minutes at a steady setting.
Flats and newer homes in Sale tend to have exposed bar valves on the bath wall, supplied by combi boilers, and their problems are often about supply more than the valve. Read on for the method.
Blocks around the Metrolink stop commonly have a thermostatic bar mixer over the bath, supplied by a combi boiler and a mains cold feed. A combi boiler has a limited flow rate, so a shower that starts hot may fade as the boiler reaches its limit, or turn cold if another tap is opened. A thermostatic valve cannot create heat that the boiler cannot supply, and it will keep reducing the hot side to hold the setting.
Exposed bar valves are simple, with a cartridge and a shut-off on each side. Scale builds in the cartridge and the filters at the inlets, and a blocked filter cuts the hot flow completely. Flats may also share a riser, so pressure in one drops when a neighbour showers. If you rent, say so, and record when you told the landlord, since the valve is usually part of the fixtures.
Thermostatic shower repairs include bar valves that cool and fade, dials that stick, inlet filters that clog, hoses that kink and showers that lose temperature when another tap opens. Sale residents can say how the shower behaves, what supplies it and who owns the fixtures, and a reader can separate valve faults from supply limits.
Run the shower at a steady setting for five minutes and write down the temperature every minute. Do the same at the kitchen tap. Photograph the valve and the bottom of the bar where the inlets sit. If a flat shares a riser, ask neighbours whether they notice the same fading. Do not unscrew the inlet filters while the supply is on, and tell your landlord promptly. Mention what time of day you shower, and whether the hot water has been on a timer, because a boiler that has only just started up will not give the valve enough hot supply and can mimic a fault.
Note the temperature each minute for five minutes at a steady setting.
Compare the shower with the kitchen tap. If both fade, the boiler may be the limit.
Blocked filters at the valve inlets cut hot flow. Photograph the inlet area.
For flats, ask neighbours whether showers affect each other.
A tenant in a recent block beside the Metrolink finds the shower opens hot but cools to lukewarm after five minutes. They log the temperature each minute, compare the kitchen tap, which fades similarly, photograph the valve and the inlet area, ask a neighbour who reports the same, and write to the agent that afternoon. They write that the boiler is a combi about six years old. A reader sees a supply limit rather than a valve fault.
Combi limits and filters. Keep a log.
Neighbours' demand. Ask them.
Landlord fixtures. Record the report date.
A shower valve in the form of a horizontal bar mounted on the wall, with dials at each end.
A small mesh in the hot and cold inlets of a valve that traps debris and can clog.
The maximum volume of hot water per minute that a combination boiler can heat.
A minute-by-minute log, a comparison with the kitchen tap and a note of the boiler type.
In flats on a shared riser, it can. Say whether neighbours notice the same, and when.
Only with the supply isolated. Say if you did, and whether the flow improved.
The tenancy answers that. Quote its wording and the date you reported the fault.
Not at all. Boilers have limits too, so a comparison with other taps helps a reader decide.
Log the temperature each minute, compare the kitchen tap and ask a neighbour. Then send your Sale thermostatic shower enquiry.
Submitting a repair enquiry does not confirm an appointment or payment.