Wet-day trips
Write down each date a breaker tripped and whether it had rained.
Electrical faults near the moors often have a weather story. A cottage with cable clipped along stone, a house at the far end of a long cable from the board and a meter box facing the wind each bring their own sort of trouble.
Stone cottages are difficult to rewire, and cables were often clipped to the surface of a wall or run through a chase cut long ago. Insulation that has been cold and damp for years turns brittle, and sockets at floor level collect moisture from the wall behind them. Name the rooms where cable is visible, including any cupboard or loft, whether any clip has pulled away, whether a socket plate feels cold or looks stained, whether a breaker trips after wet weather and when the cottage was last rewired. Add whether the roof space has been insulated or boarded, since cable buried under insulation runs warmer and ages differently from cable left in air.
Larger houses by the lake have long cable routes between board and bedroom, and a supply that arrives overhead is exposed to gales. Lights may dim when a heater starts and flicker when the wind rises. Say where the supply enters, whether the meter box is cracked, whether lights dim when a cooker or shower starts, whether neighbours see the same and whether the board sits in a cold outhouse or a warm hall. A photograph of the supply cable where it meets the house wall, taken from the ground, shows its condition without anyone climbing.
Electrical work in Littleborough covers breakers that trip after rain, sockets that stop working on outside walls, lights that flicker in gales and boards that sit in cold places. Because so much here depends on weather and wall type, a reader gets most from dates, conditions and the wall a faulty fitting sits on.
Turn the circuit off at the board if a plate is damp, scorched or smells hot, and leave it off. Photograph the board with its cover shut, the plate and the cable entry on the outside wall. Keep fingers out of a damp socket, never run a lead from another room across a wet floor and avoid going up a ladder to inspect an overhead cable. Dial 105 if the whole street has lost power.
Write down each date a breaker tripped and whether it had rained.
Feel sockets on outside walls and note any that are cold or stained.
Note which appliance makes lights dim as it starts.
Photograph where the supply cable and meter box meet the wall.
In a stone cottage near the canal the kitchen breaker trips after every wet spell, a socket on the outside wall is cold and slightly stained and the hall light flickers in a gale. The householder lists the wet days, photographs the closed board and the stained plate, notes that the cable runs along the surface of the wall and finds a crack in the meter box. A reader sees damp reaching a fitting on an outside wall and a service point open to the weather.
Brittle and cold. Photograph the run.
Damp plates. Feel and note.
Cracks at the service point. Photograph the box.
Cable fixed along the face of a wall instead of being buried inside it.
A slim channel cut in a wall to carry a cable or pipe.
A cable that reaches a house through the air from a pole.
Damp may reach a fitting. List the wet days and photograph the plate.
Better not. Switch the circuit off and photograph the faceplate.
Perhaps the service point; ask neighbours whether they see it too.
Leave it be; photograph it from a distance instead.
Typing comes first here too; visiting depends on a quote you have accepted.
Turn the circuit off, list the wet days, photograph the closed board, the stained plate and the cracked box, and then send your Littleborough electrical details to Repairco.