Trunking
Note cracked trunking and where cable leaves it to reach a socket.
Oldham's old mills have become flats and its steep terraces are cold and damp, and both ask a lot of the electrics. Large open rooms need long circuits, and walls that run with condensation give breakers and connections a hard time.
Mill conversions run cable in surface trunking along brick walls and across floors, with sockets at the end of long runs and a consumer unit that serves the whole flat. Trips follow the most heavily loaded circuit. Describe how big the flat is, where the trunking runs, how many sockets share a breaker, which appliances run together and who looks after the building's incoming supply. Add the height of the ceilings and the material of the walls, since tall brick rooms mean longer cable runs and sockets set far from the board, and the further a socket is from its source the more a heavy load shows.
Terraces on steep streets keep their meters and boards in cold cellars and under stairs, where condensation forms on metal. Wet weather brings trips and corroded terminals. Place the board, then say if the wall around it is wet, if trips follow rain or frost, if the board hums and if any smell has been noticed.
Typical work includes breakers that trip in damp spells, sockets that stop at the end of long runs, trunking fittings that crack and old fused spurs that blow. A reader gets the best idea from a description of how the home is used and how damp the board position is, rather than from any one fitting.
Write down the trip dates and the weather. Photograph the closed board and the cracked trunking run, with a coin beside it for scale. Count the sockets on the circuit that trips, and note how far the farthest one is from the board, because the end of a long run is where weakness shows first. Leave a circuit that trips at once switched off. Do not remove trunking covers, do not run extension leads from a neighbouring flat and do not dry a damp board with a heater. Say whether the supply is shared with other flats.
Note cracked trunking and where cable leaves it to reach a socket.
Say whether the wall near the board is wet and whether labels have peeled.
List the appliances on any circuit that trips.
In a flat, say whether the incoming supply is shared.
In a mill-conversion flat, a household finds the kitchen end sockets die when the oven and the washer run together, while a terrace relative's cellar board trips on wet mornings. The flat household lists the appliances, photographs a cracked trunking cover, notes the board is shared with the flat next door, records four trips and leaves the circuit off. The relative notes damp on the cellar wall and a hum from the board. The finding is a heavy circuit far from its source and a board standing in damp air.
Long runs. List loads by circuit.
Damp air. Log trips against weather.
Blown fuses. Describe what is on them.
A duct of plastic or steel fixed on a wall surface to hold cables where burying them is impossible.
The cabinet that splits a home's supply into circuits, each guarded by a switch that trips when overloaded.
Water that gathers when warm humid air meets a cold surface, like a board in a cellar.
Probably loaded. List what runs and photograph the trunking.
Please not. Record the days and photograph the wall.
No. Take it as found, in a photograph.
Usually the building's manager. Ask, then write the answer down.
Not by itself. You get a reply in writing, and any visit waits on a quote you accept.
List the trip dates with the weather, picture the board and cracked trunking, leave tripping circuits off and then lodge your Oldham electrical enquiry with Repairco.
Submitting a repair enquiry does not confirm an appointment or payment.