Which floors share
Work out which floors and rooms lose power together.
A big Prestwich house asks a great deal of its wiring: many rooms, many lights and a layout altered by several owners. The faults that arrive are usually the patient kind, a socket that has been warm for months or a circuit that trips only when everything is on.
Villas near Heaton Park were wired room by room as electricity became affordable, and some still run a single lighting circuit through three floors on cable that is a century old. Added kitchens and bathrooms hang from newer circuits spliced into the old ones. A flickering landing light may sit on the same cable as the attic bedroom. Describe which floors share a switch or a fuse, which rooms were rewired and which were not, and where the board or boards sit.
Semis from between the wars were often wired in rubber-insulated cable, which hardens and cracks in loft spaces and behind plaster as it ages. Houses near the clough also meet damp, and a board in a cellar cupboard may grow rust at its base. Mention any rubber cable you have seen, whether the board is in a cellar or hall, whether the wall near it is damp and whether trips follow wet weather.
Electrical work in houses like these covers sockets that run warm, lights that flicker on a long run, boards that trip when two heavy appliances start and fittings that fail in damp rooms. The age of the wiring and the pattern of the trips are what a reader weighs first, ahead of any particular part.
Keep a short diary of each trip, with what was running and what the weather was doing. Picture the shut board and any socket plate that has gone dark, and leave a warm fitting switched off at the board. Never open a plate, never push a tripped breaker back repeatedly and never use a lead from another room to rescue a dead circuit. Mention how many sockets each main room has.
Work out which floors and rooms lose power together.
Describe any cloth or rubber covering seen in a loft or cupboard.
Name the room the board is in and say if its wall is damp.
Note any socket or switch that is warm or marked.
In a three-storey villa by the park, the attic landing light flickers each time the dishwasher starts on the floor below, a double socket in the dining room runs warm and the cellar board has rust at its foot. The household keeps a diary of nine flickers, notes the dishwasher and the oven were on at the time, photographs the closed board and the darkened plate, leaves the warm socket off at the board and says the top floor was never rewired. A reader sees a long old lighting circuit and a socket that should rest.
Long lighting circuits. Map which rooms share.
Brittle sheaths. Note what you see in the loft.
Damp and rust. Look from a distance, no touching.
The distinct cable run serving ceiling lights and their switches, lighter in build than the sockets' wiring.
An old cable covering that stiffens and cracks with age, exposing the copper beneath.
A joint where one cable is connected to another, often made when a circuit is extended.
Probably on shared cable. Keep a diary of each flicker with what was running.
Please keep it off at the board and mention that in your note.
Never. Look from a distance and take a picture.
Please not. Describe the flicker and the floor.
Not by being sent. The reply you receive is in writing, and a visit waits on a quote you accept.
Keep a diary of each trip, picture the shut board and any darkened plate, hold warm fittings off at the board and finish by posting your Prestwich electrical enquiry to Repairco.
Submitting a repair enquiry does not confirm an appointment or payment.